  the copyright and authority for the interpretation of the products are reserved by mornsun td100-ex-485-xx 2013.06.19-a/2 page 1 of 3 detection safety barrier rs485 input rs485 output (half-duplex) td100-ex-485-xx series part number system td100-ex-485-xx 485 signalinput productseries channel number serial number isolationbarriermark features l three-port isolation (input, output and power supply) l high isolation voltage (2500vac/60s) l high reliability (mtbf>500,000 hours) general description td-ex detection side isolated safety barrier, it can supply isolated dc power of the transmitters from the security zone to the danger zone, transform the rs-485 digital signal of danger zone into isolated rs-485 digital signal transmission to the security zone, while increasing the anti-jamming capability of the industrial production process control system, to ensure system stability and reliability. it meets iec/en61326 standards. one independent power supply is required. moreover, within the product power supply, input and output are mutually isolated. field devices connected with this product: rs-485 bus selection guide power supply 18~32vdc typ. :24vdc power dissipation about 2.8w power power protection reverse protection input signal: rs-485 half-duplex digital signal hazardous area on-site power supply: 5v, 6v: i 100ma 8v, 9v: i 50ma safe area rs-485 half-duplex digital signal signal characteristics rs-485 signal level rules: standard rs-485 differential level transmission delay: 10 s signal transmission rate: 56kbps isolation characteristics galvanic isolation intrinsically safe end and non-intrinsically safe end 2500vac 1min emc characteristics re cispr22/en55022 class a emi ce cispr22/en55022 class a esd iec/en61000-4-2 air 6kv/contact 4kv perf. criteria b rs iec/en61000-4-3 3v/m perf. criteria a eft iec/en61000-4-4 1kv perf. criteria b iec/en61000-4-5 dc power port 1kv / 2kv perf. criteria b surge i/o signal port 1kv(pe) perf. criteria b ems cs iec/en61000-4-6 3 vr.m.s perf. criteria a other characteristics green: power, lighting at power on. yellow: send indicator, safety side lights when data is sending. signal indicator red: receive indicator, safety side lights when data is receiving.
the copyright and authority for the interpretation of the products are reserved by mornsun td100-ex-485-xx 2013.06.19-a/2 page 2 of 3 operation temperature: -25 c ~ +71 c ambient temperature transport and storage temperature: -50 c ~ +105 c field devices connected and regions equipment with rs-485 communication interface zone 0, zone 1, zone 2, ii a, ii b, ii c, t4~t6 danger zone package 35mm din-rail package: pluggable connection pin, thickness 22.5mm,plastic ul94-v0 safety class ip20(iec60529 / en60529) weight about 150g explosion protection explosion protection mark [exia ga] ii c between the pin 9 and 10 u o =11.2 v, i o =111ma, p o = 0.31w, u m =250v c o =1.2 f, l o =2mh certification parameters between the pin 11 and 12 u o =12.6v, i o =306ma , p o =0.96mw, u m =250v c o =0.7 f, l o =0.21mh explosion protection certificate agency national quality supervision and test centre for explosion protected electrical products explosion qualified no. cnex11.2587 isolation power output curve 5v/6v isolation power output curve 0 1 2 3 4 5 6 7 0 30 60 90 120 output current io(ma) output voltage vo(v) 5v 6v 8v/9v/12v isolation power output curve 0 2 4 6 8 10 12 14 0 20 40 60 80 output current io(ma) output voltage vo(v) 8v 9v 12v application connection 1. removable terminal; 2. cross section area of wiring: 0.5mm2 ~2.5 mm2; 3. the length of bare wire is about 8mm, locked up by the m3 bolt. application in intrinsically safe explosion protection system in intrinsically safe explosion protection systems, isolating barrier belongs to affiliated device. it is installed at safe area, as a connection between intrinsically safe devices in the hazardous area and non-intrinsically safe devices in the safe area. by limiting the energy to a certain safe threshold, it ensures the safety of field devices and people. selection guidelines for intrinsically safe explosion protection system 1. the explosion protection grade of the barrier must be not less than that of intrinsically safe explosion protection device in spot. 2. take inconsideration of hazardous end output resistance and loop resistance make sure the barrier output voltage meets the minimum operation voltage requirement of intrinsically safe device in spot. 3. the safety parameters about intrinsically safe end meets: uo ui, io iin, po pin co cin, lo lin 4. select suitable safety barrier which matches the intrinsically safe device in spot according to the power polarity, signal type and transmission mode about the device. 5. much more protection is required, which can avoid the influence of the leakage current generated by safety barrier on intrinsically safe device in spot. 6. the wires leading to dangerous field should be constrainted in blue intrinsically safe wires, and its copper cross-section should be more than 0.5mm 2 ; insulation intensity should be more than 500vdc. operation notes 1. please read the user manual carefully before using. if any question please contact our technical support department. 2. please do not use this product in hazardous area. 3. the power supply of this product should be 24vdc power source. it is forbidden to use 220vac power supply. 4. to avoid invalid explosion protection function, or any failure, users disassemble this product is forbidden. after service 1. products are carefully inspected and controlled before going out from our factory. if they operated abnormally or there were anything wrong in the inner parts, please contact with our agents near you or technical support in our company as soon as possible. 2. 3 years warranty since the delivery date. during the period of quality guarantee, our company will repair or change free of charge if product has any quality problem in the process of normally using.
the copyright and authority for the interpretation of the products are reserved by mornsun td100-ex-485-xx 2013.06.19-a/2 page 3 of 3 application circuit diagram 1 2 4 3 11 12 9 10 rs-485 rs-485 a b a b a b a b + - + - + - 24vdc dcs plc safe-area hazardous-area power supply installation & disassembly installation din35mm standard rail installation: 1. insert the top of the instrument card in the rail; 2. push the bottom of the instrument into the rail. disassembly 1. insert a screwdriver between the bottom of the card lock and the rail; 2. pull up the screwdriver and press the card lock downwards; 3. pull the instrument out of the rail. 1 2 3 packaging dimension & packaging diagram note: 1. all specifications are measured at ta=25 c, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2. in this datasheet, all the test setup and methods are based on our corporate standards. 3. all characteristics are meant for listed model, non-standard models may perform differently, you can contact mornsun fae for more details. 4. contact us for your specific requirement. 5. specifications are subject to change without prior notice. mornsun science & technology co.,ltd. address: no. 5, kehui st. 1, kehui development center, science ave., guangzhou science city, luogang district, guangzhou,p.r.china. tel: 86-20-38601850 fax:86-20-38601272 e-mail: info@mornsun.cn http://www.mornsun-power.com


▲Up To Search▲   

 
Price & Availability of TD100-EX-485-RE

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X